M-Glass Shaft Liner panels consist of a fire-resistant type X gypsum core that is encased in a moisture and mold resistant glass mat fabric. The panels feature a double beveled edge for ease of installation, with the ends being square-cut and finished smooth. M-Glass Shaft Liner panels are available: 1" thick x 2' wide, and in a variety of lengths.
American Gypsum products contain no asbestos and no detectable levels of formaldehyde.
M-Glass Shaft Liner panels are UL Classified (UL Type - M-Glass) and used in conjunction with other American Gypsum products and metal framing members for Shaftwall and Area Separation Wall systems. Lightweight non-load bearing gypsum Shaftwall systems have replaced traditional masonry for interior vertical enclosures including stairwells, elevator enclosures and mechanical chases.
American Gypsum’s M-Glass Shaft Liner is manufactured to meet or exceed the requirements of ASTM C1658/C1396, and was developed for and is backed by a limited warranty for exposure up to 12 months under normal weather conditions on commercial and residential projects.
American Gypsum’s M-Glass Shaft Liner panels have been approved for use in the following fire rated assemblies:
M-Glass Shaft Liner panels have achieved UL Environment’s GREENGUARD GOLD Certification. GREENGUARD Certified products are scientifically proven to meet some of the world’s most rigorous, third-party chemical emissions standards, helping reduce indoor air pollution and the risk of chemical exposure while aiding in the creation of healthier indoor environments. For more information, visit www.ul.com/gg.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
1" (25.4mm) | 2' (610mm) | 8'-12' (2438mm-3658mm) | Double Beveled |
Special lengths or edges may be available on special order. Consult your American Gypsum sales representative for details.
Material must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
M-Glass Shaft Liner that has visible mold growth must not be used. For additional information refer to Gypsum Association publication, “Guidelines for the Prevention of Mold Growth on Gypsum Wallboard” (GA-238).
Mold Resistance | Score of 10 (ASTM D 3273) |
---|---|
Water Absorption | <10 (ASTM C1177, section 5.2.5) ASTM C1658, C1396 |
Surface Burning Characteristics | ASTM E 84 Flame Spread 0 Smoke Developed 0 |
Combustability | Non-Combustible (ASTM E 136) |
Call (866) 439-5800 or Send Email
M-Glass Exterior Sheathing is a high performance mold and moisture resistant panel designed for direct attachment to exterior side-wall and soffit framing as a underlayment for various exterior materials such as wood, metal or vinyl siding, properly detailed Exterior Insulation Finish Systems (EIFS), masonry veneer, stucco, shingles, etc. It is produced in 1/2” and 5/8” thicknesses with the 5/8” M-Glass Exterior Sheathing having a UL classified formulated Type X core for use in approved fire rated assemblies.
American Gypsum products contain no asbestos and no detectable levels of formaldehyde
American Gypsum’s M-Glass Exterior Sheathing is manufactured to meet or exceed the requirements of ASTM C1177, and was developed for and is backed by a limited warranty for exposure up to 12 months under normal weather conditions on commercial and residential projects. M-Glass Exterior Sheathing provides mold, moisture and fire resistance protection when attached directly to exterior side-wall or soffit framing
for use as a underlayment for finishes such as wood, metal or vinyl siding, properly detailed Exterior Insulation Finish Systems (EIFS), masonry veneer, stucco, shingles, etc.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
1/2" (12.7mm) | 4’ (1219mm) | 8’ (2438mm) | Square |
5/8” (15.9mm) | 4’ (1219mm) | 8’ (2438mm) | Square |
Special lengths or edges may be available on special order. Consult your American Gypsum sales representative for details.
M-Glass Exterior Sheathing board does not generate or support the growth of mold when it is properly transported, stored, handled, installed, and maintained. However, mold spores are present everywhere and when conditions are favorable; mold can grow on practically any surface. The panels must be stored off the ground and in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Sufficient risers must be used to assure support for the entire length of the wallboard to prevent sagging. M-Glass Exterior Sheathing shall always be stacked flat - NEVER on edge or end. Panels stacked on edge or end are unstable and present a serious hazard should it accidentally topple. Care must be taken so weight is evenly distributed and floors are not overloaded.
Material must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
M-Glass Exterior Sheathing that has visible mold growth must not be used. For additional information refer to Gypsum Association publication, “Guidelines for the Prevention of Mold Growth on Gypsum Wallboard” (GA-238).
Mold Resistance | Score of 10 (ASTM D 3273) |
---|---|
Manufacturing | ASTM C 1177 |
Installation | ASTM C 1280 Gypsum Association GA-253 |
Surface Burning Characteristics | ASTM E 84 Flame Spread 0 Smoke Developed 0 |
Combustability | Non-Combustible (ASTM E 136) |
Call (866) 439-5800 or Send Email
1/2” Interior Ceiling Board is specifically formulated to meet the need for a lower weight ceiling panel with increased integrity in its gypsum core, making its sag resistance equivalent to 5/8” Type X wallboard. American Gypsum’s 1/2’’ Interior Ceiling Board is designed for use in wall and ceiling applications spaced no more than 24’’ o/c, and approved to be applied parallel or perpendicular to ceiling framing spaced up to 24’’ o/c, even when a hand applied or water-based texture is used for decoration.
The exceptional sag resistance of American Gypsum’s Interior Ceiling Board has been independently verified by Progressive Engineering, Inc. when tested in accordance with ICC-ES AC417 (Acceptance Criteria for 1/2 Inch Sag-Resistant Gypsum Ceiling Board), and PEI Standard No. 94-9 - Large Scale Ceiling Board Load Test Procedure.
American Gypsum products contain no asbestos and no detectable levels of formaldahyde.
5/8" wallboard panels were once considered the best product for ceiling applications where the framing is spaced up to 24" o/c. However, product weight has always been a hindrance to proficient construction. The lighter weight 1/2" Interior Ceiling Board is specifically designed for interior ceilings in standard residential and commercial applications where framing members are spaced up to 24" o/c and a water-based texture will be used.
Interior ceiling gypsum wallboard has achieved UL Environment’s GREENGUARD GOLD Certification. GREENGUARD Certified products are scientifically proven to meet some of the world’s most rigorous, third-party chemical emissions standards, helping reduce indoor air pollution and the risk of chemical exposure while avoiding in the creation of healthier indoor environments.
For more information, visit www.ul.com/gg
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
1/2" (12.7mm) | 4' (1219mm) | 8'-12' (2438mm-3658mm) | Tapered |
Special lengths may be available on special order. Consult your American Gypsum sales representative for details.
Gypsum board does not generate or support the growth of mold when it is properly transported, stored, handled, installed, and maintained. However, mold spores are present everywhere and when conditions are favorable; mold can grow on practically any surface. GYPSUM BOARD MUST BE KEPT DRY to prevent the growth of mold.
Gypsum board must be stored in an area that protects it from adverse weather conditions, condensation, and other forms of moisture. Job site conditions that can expose gypsum board to water or moisture must be avoided.
Gypsum board must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
Gypsum board that has visible mold growth must not be used. For additional information, refer to Gypsum Association publication,
"Guidelines for the Prevention of Mold Growth on Gypsum Wallboard" (GA-238).
Gypsum board must be stored off the ground and under protective cover. Sufficient risers must be used to assure support for the entire length of the wallboard to prevent sagging.
Gypsum board must be delivered to the job site as near to the time it will be used as possible. Individuals delivering gypsum board to jobsites should ensure that it is carried, not dragged, to place of storage/installation to prevent damage to finished edges.
Gypsum board shall always be stacked flat - NEVER on edge or end. Gypsum board stacked on edge or end is unstable and presents a serious hazard should it accidentally topple. Gypsum board should be placed so weight is evenly distributed and the floor is not overloaded.
Manufacturing | ASTM C 1396 section 12 (C 1395) Federal Specification SS-L-30D Type III |
---|---|
Installation | ASTM C 840 Gypsum Association GA-216 Gypsum Association GA-214 |
Surface Burning Characteristics | ASTM E 84 Flame Spread 0 Smoke Developed 0 |
LEED Contributions
Our products can contribute to the following credits within the Materials and Resources (MR) category.
Our products can contribute to the following credit within the Indoor Environmental Quality (IEQ) category.
To learn more please click the LEED link at right.
Call (866) 439-5800 or Send Email
American Gypsum’s 1” M-Bloc® Shaft Liner gypsum panels consist of a fire-resistant type X core that is encased in a mold and moisture resistant blue face and back paper manufactured from 100% recycled paper. The face paper is folded around the long edges to reinforce and protect the core. The panels feature a double beveled edge for ease of installation, with the ends being square-cut and finished smooth. M-Bloc Shaft Liner panels are available: 1” thick x 2’ wide, and in a variety of lengths. At an independent laboratory accredited in accordance with ISO 17025-2005, M-Bloc panels have been tested to the industry’s most rigorous standards achieving the best possible results per ASTM D3273, scoring a perfect 10 thus minimizing the risk of mold and mildew growth.
M-Bloc Shaft Liner panels are used in conjunction with other American Gypsum products and metal framing members for Shaftwall and Area Separation Wall systems. M-Bloc Shaft Liner may be substituted for American Gypsum’s standard 1” Shaft Liner panels. Lightweight non-load bearing gypsum Shaftwall systems have replaced traditional masonry for interior vertical enclosures including stairwells, elevator enclosures and mechanical chases.
American Gypsum’s M-Bloc Shaft Liner has been approved for use in the following assemblies:
M-Bloc Shaft Liner gypsum wallboard has achieved UL Environment’s GREENGUARD GOLD Certification. GREENGUARD Certified products are scientifically proven to meet some of the world’s most rigorous, third-party chemical emissions standards, helping reduce indoor air pollution and the risk of chemical exposure while aiding in the creation of healthier indoor environments. For more information, visit www.ul.com/gg. To obtain product certificate, please select the GREENGUARD link to the right.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
1" (25.4mm) | 2' (610mm) | 8' - 14' (2438mm - 4267mm) | Double Beveled |
Special lengths or edges may be available on special order. Consult your American Gypsum sales representative for details.
Gypsum board does not generate or support the growth of mold when it is properly transported, stored, handled, installed, and maintained. However, mold spores are present everywhere and when conditions are favorable; mold can grow on practically any surface. GYPSUM BOARD MUST BE KEPT DRY to prevent the growth of mold.
Gypsum board must be stored in an area that protects it from adverse weather conditions, condensation, and other forms of moisture. Job site conditions that can expose gypsum board to water or moisture must be avoided.
Gypsum board must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
Gypsum board that has visible mold growth must not be used. For additional information, refer to Gypsum Association publication,
"Guidelines for the Prevention of Mold Growth on Gypsum Wallboard" (GA-238).
Gypsum board must be stored off the ground and under protective cover. Sufficient risers must be used to assure support for the entire length of the wallboard to prevent sagging.
Gypsum board must be delivered to the job site as near to the time it will be used as possible. Individuals delivering gypsum board to jobsites should ensure that it is carried, not dragged, to place of storage/installation to prevent damage to finished edges.
Gypsum board shall always be stacked flat - NEVER on edge or end. Gypsum board stacked on edge or end is unstable and presents a serious hazard should it accidentally topple. Gypsum board should be placed so weight is evenly distributed and the floor is not overloaded.
Mold Resistance | Score of 10 (ASTM D 3273) |
---|---|
Manufacturing | ASTM C 1396 section 6 (C 442) Federal Specification – SS-L-30D Type IV Grade X |
Installation | ASTM C 840 Gypsum Association GA-216 Gypsum Association GA-214 Gypsum Association GA-620 |
Surface Burning Characteristics | ASTM E 84 Flame Spread 0 Smoke Developed 0 |
LEED Contributions
Our products can contribute to the following credits within the Materials and Resources (MR) category.
Our products can contribute to the following credit within the Indoor Environmental Quality (IEQ) category.
To learn more please click the LEED link at right.
Call (866) 439-5800 or Send Email
M-Bloc® Type C gypsum panels were developed as an improved mold and moisture resistant wallboard with additional properties to enhance the core of this type X wallboard to achieve superior performance when used in specific fire rated assemblies. M-Bloc Type C panels are encased in a mold and moisture resistant blue face paper and brown back paper manufactured from 100% recycled paper. At an independent laboratory accredited in accordance with ISO 17025-2005, M-Bloc panels have been tested to the industry’s most rigorous standard achieving the best possible results per ASTM D3273, scoring a perfect 10 thus minimizing the risk of mold and mildew growth.
M-Bloc Type C gypsum panels are used as a covering for walls and ceilings in residential and commercial applications that often require specific fire rated assemblies. M-Bloc Type C gypsum panels can be used throughout a project as well as the adhesive application of ceramic or plastic tile in limited wet areas, e.g., bathrooms, kitchens, laundry, and utility rooms. M-Bloc Type C gypsum panels are also approved for application to exterior soffits and/or sidewalls in protected corridors/breezeways with indirect exposure to the weather.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
5/8" (15.9mm) | 4' (1219mm) | 8'-12' (2438mm-3658mm) | Tapered |
Call (866) 439-5800 or Send Email
M-Bloc® gypsum panels were developed as an improved mold and moisture resistant wallboard with a fire resistant core encased in a mold and moisture resistant blue face paper and brown back paper manufactured from 100% recycled paper. At an independent laboratory accredited in accordance with ISO 17025-2005, M-Bloc panels have been tested to the industry’s most rigorous standard achieving the best possible results per ASTM D 3273 scoring a perfect 10, thus minimizing the risk of mold and mildew growth.
M-Bloc gypsum panels are a lightweight cost efficient interior wall or ceiling panel for use throughout a project as well as the adhesive application of ceramic or plastic tile in limited wet areas, e.g., bathrooms, kitchens, laundry, and utility rooms. M-Bloc gypsum panels are also approved for exterior soffits and/or sidewalls in protected corridors/breezeways with indirect exposure to the weather.
M-Bloc interior gypsum panels have achieved UL Environment’s GREENGUARD GOLD Certification. GREENGUARD Certified products are scientifically proven to meet some of the world’s most rigorous, third-party chemical emissions standards, helping reduce indoor air pollution and the risk of chemical exposure while aiding in the creation of healthier indoor environments. For more information, visit www.ul.com/gg. To obtain product certificate, please select the GREENGUARD link to the right.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
1/2" (12.7mm) | 4' (1219mm) | 8'-12' (2438mm-3658mm) | Tapered |
Gypsum board does not generate or support the growth of mold when it is properly transported, stored, handled, installed, and maintained. However, mold spores are present everywhere and when conditions are favorable; mold can grow on practically any surface. GYPSUM BOARD MUST BE KEPT DRY to prevent the growth of mold. Adequate ventilation shall be provided to prevent condensation.
Gypsum board that has visible mold growth must not be used. For additional information refer to Gypsum Association publication, “Guidelines for the Prevention of Mold Growth on Gypsum Wallboard” (GA-238).
Gypsum board must be stored in an area that protects it from adverse weather conditions, condensation, and other forms of moisture. Job site conditions that can expose gypsum board to water or moisture must be avoided.
Gypsum board must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
Gypsum board must be delivered to the job site as near to the time it will be used as possible. Individuals delivering gypsum board to jobsites should ensure that it is carried, not dragged, to place of storage/installation to prevent damage to finished edges.
Mold Resistance | Score of 10 (ASTM D 3273) |
---|---|
Manufacturing | ASTM C 1396 section 5 (C 36) Federal Specification - SS-L-30D Type III Grade X |
Installation | ASTM C 840 Gypsum Association GA-216 Gypsum Association GA-214 |
Surface Burning Characteristics | ASTM E 84 Flame Spread 0 Smoke Developed 0 |
Call (866) 439-5800 or Send Email
LightRoc® Type X gypsum wallboard panels are engineered to be lighter in weight than traditional Type X wallboard, yet maintain the same performance standards the industry has come to depend on for almost 60 years from American Gypsum. With its UL classification (LightRoc), this panel is approved for use in over 100 fire rated assemblies including walls, ceilings, horizontal membranes, shaftwalls, columns, beams and head-of-wall details. The fire-resistant gypsum core is encased in 100% recycled natural-finish paper on the face side and sturdy liner paper on the back side. Long edges of the panels are tapered or square, with tapered edges allowing joints to be easily reinforced and finished with the joint treatment systems.
American Gypsum products contain no asbestos and no detectable levels of formaldehyde.
Currently this product is limited to the South Region. Please check with your local American Gypsum sales representative for availability.
American Gypsum’s lightweight 5/8’’ LightRoc Type X wallboard is normally used to achieve specific fire rated assemblies in commercial and residential applications. It is designed for direct attachment by screws, nails, or adhesive to wood or metal framing and even existing surfaces.
With joints covered, LightRoc Type X gypsum wallboard will resist the passage of smoke. For additional information on smoke barriers, refer to Gypsum Association publication, “Building and Inspecting Smoke Barriers” (GA-618).
LightRoc Type X gypsum wallboard has attained the GREENGUARD Indoor Air Quality Certified status and GREENGUARD Children & Schools Indoor Air Quality Certified status.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
5/8” (15.9mm) | 4’ (1219mm) | 8’ - 12’ (2438mm – 3658mm) | Tapered |
Special lengths or edges may be available on special order. Consult your American Gypsum sales representative for details.
Weight 2.04 lb. s/f *
Thermal Resistance “R” Value 5/8” = 0.61
* (Represents approximate weight for design and shipping purposes. For specific product weight in your area consult the local American Gypsum sales representative.)
Gypsum board does not generate or support the growth of mold when it is properly transported, stored, handled, installed, and maintained. However, mold spores are present everywhere and when conditions are favorable; mold can grow on practically any surface. GYPSUM BOARD MUST BE KEPT DRY to prevent the growth of mold.
Gypsum board must be stored in an area that protects it from adverse weather conditions, condensation, and other forms of moisture. Job site conditions that can expose gypsum board to water or moisture must be avoided.
Gypsum board must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
Gypsum board that has visible mold growth must not be used. For additional information, refer to Gypsum Association publication,"Guidelines for the Prevention of Mold Growth on Gypsum Wallboard" (GA-238).
Gypsum board must be stored off the ground and under protective cover. Sufficient risers must be used to assure support for the entire length of the wallboard to prevent sagging.
Gypsum board must be delivered to the job site as near to the time it will be used as possible. Individuals delivering gypsum board to jobsites should ensure that it is carried, not dragged, to place of storage/installation to prevent damage to finished edges.
Gypsum board shall always be stacked flat - NEVER on edge or end. Gypsum board stacked on edge or end is unstable and presents a serious hazard should it accidentally topple. Gypsum board should be placed so weight is evenly distributed and the floor is not overloaded.
Manufacturing | ASTM C 1396 section 5 (C 36) |
---|---|
Installation | ASTM C 840 Gypsum Association GA-216 |
Nail Pull, Humidified, Deflection, Flexural Strength, Core Hardness | ASTM C 473 |
Surface Burning Characteristics | ASTM E 84 |
LEED Contributions
Our products can contribute to the following credits within the Materials and Resources (MR) category.
Our products can contribute to the following credit within the Indoor Environmental Quality (IEQ) category.
To learn more please click the LEED link at right.
Call (866) 439-5800 or Send Email
M-Bloc® IR Type X interior gypsum panels were designed and tested to not only provide exceptional resistance to mold and moisture, but superior resistance to impact penetration, abrasion, abuse and indention when compared to traditional wallboard. This Type X panel consist of an impact, abuse defiant core encased in heavy abrasion, mold and moisture resistant blue face paper and brown back paper manufactured from 100% recycled paper, with a fiberglass mesh fabric embedded into the core adjacent to the back of the panel to provide additional impact and penetration resistance. At an independent laboratory accredited in accordance with ISO 17025-2005, M-Bloc panels have been tested to the industry’s most rigorous standard achieving the best possible results per ASTM D3273, scoring a perfect 10 thus minimizing the risk of mold and mildew growth.
M-Bloc IR Type X interior gypsum panels are recommended for commercial and institutional construction where greater resistance to impact, abrasion, abuse and indentation are required. These UL classified panels are allowed for use in any fire rated design where American Gypsum’s 5/8” Type X wallboard is approved. Additionally M-Bloc IR Type X panels can be used as a base for the adhesive application of ceramic or plastic tile in limited wet areas, e.g., bathrooms, kitchens, laundry, and utility rooms.
Shaft liner gypsum wallboard has attained the GREENGUARD Indoor Air Quality Certified status and GREENGUARD Children & Schools Indoor Air Quality Certified status. For more information click on the link at right.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
5/8" (15.9mm) | 4' (1219mm) | 8' (2438mm) | Tapered |
5/8" (15.9mm) | 4' (1219mm) | 10' (3048mm) | Tapered |
5/8" (15.9mm) | 4' (1219mm) | 12' (3658mm) | Tapered |
Special lengths or edges may be available on special order. Consult your American Gypsum sales representative for details.
Thermal Resistance “R” Value 5/8” = 0.61
Installation - M-Bloc IR Type X shall be installed in accordance with the recent editions of “Application and Finishing of Gypsum Panel Products” (GA-216) and or “Standard Specification for Application and Finishing of Gypsum Board” (ASTM C 840).
The building temperature shall be maintained at not less than 50ºF (10ºC) for adhesive application of gypsum board, during joint treatment, texturing, and decoration. When a temporary heat source is used the temperature shall not be more than 95°F (35°) in any given room or area. Adequate and continuous ventilation shall be provided in the working area during the installation and the drying or curing period.
The listed impact penetration/abrasion/abuse/indention ratings apply to walls constructed with M-Bloc IR Type X gypsum wallboard installed vertically to minimum 20 gauge framing members spaced a maximum of 16" o/c.
The design professional has the ultimate responsibility for location of control joints.
Decoration - The design professional, contractor and or owner shall review “Recommended Levels of Gypsum Board Finish” (GA-214), in order to specify the proper level of drywall finishing needed to assure the desired results. For best painting results, all surfaces, including joint compound, should be clean, dust-free and not glossy. To equalize the porosities between the face paper and joint compound and improve fastener and joint concealment, the surface shall be primed and sealed with a full-bodied high solids drywall primer before texturing or final decoration. The selection of the proper paint to give the specified or desired finished characteristics is the responsibility of the design professional, contractor and or owner.
Mold Resistance | Score of 10 (ASTM D 3273) |
---|---|
Manufacturing | ASTM C 1396 Federal Specification - SS-L-30D Type III Grade X |
Abrasion Resistance | Level 3 |
Indentation Resistance | Level 1 |
Soft Body Impact Resistance | Level 3 |
Hard Body Impact Resistance | Level 3 |
Surface Burning Characteristics | ASTM E 84 Flame Spread - 0 Smoke Developed - 0 |
LEED Contributions
Our products can contribute to the following credits within the Materials and Resources (MR) category.
Our products can contribute to the following credit within the Indoor Environmental Quality (IEQ) category.
To learn more please click the LEED link at right.
Call (866) 439-5800 or Send Email
M-Bloc® AR Type X interior gypsum panels were designed and tested to not only provide exceptional resistance to mold and moisture, but superior resistance to abrasion, abuse and indention when compared to traditional wallboard. This Type X panel consist of an abuse defiant core encased in heavy abrasion, mold and moisture resistant blue face paper and brown back paper manufactured from 100% recycled paper. At an independent laboratory accredited in accordance with ISO 17025-2005, M-Bloc panels have been tested to the industry’s most rigorous standard achieving the best possible results per ASTM D3273, scoring a perfect 10 thus minimizing the risk of mold and mildew growth.
M-Bloc AR Type X interior gypsum panels are recommended for commercial and institutional construction where greater resistance to abrasion, abuse and indentation are required. These UL classified panels are allowed for use in any fire rated design where American Gypsum’s 5/8” Type X wallboard is approved. Additionally M-Bloc AR Type X panels can be used as a base for the adhesive application of ceramic or plastic tile in limited wet areas, e.g., bathrooms, kitchens, laundry, and utility rooms.
M-Bloc IR Type X interior gypsum panels have achieved UL Environment’s GREENGUARD GOLD Certification. GREENGUARD Certified products are scientifically proven to meet some of the world’s most rigorous, third-party chemical emissions standards, helping reduce indoor air pollution and the risk of chemical exposure while aiding in the creation of healthier indoor environments. For more information, visit www.ul.com/gg
To obtain product certificate, please select the GREENGUARD link to the right.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
5/8" (15.9mm) | 4' (1219mm) | 8' (2438mm) | Tapered |
5/8" (15.9mm) | 4' (1219mm) | 10' (3048mm) | Tapered |
5/8" (15.9mm) | 4' (1219mm) | 12' (3658mm) | Tapered |
Special lengths or edges may be available on special order. Consult your American Gypsum sales representative for details.
Thermal Resistance “R” Value 5/8” = 0.61
M-Bloc AR Type X interior gypsum panels do not generate or support the growth of mold when they are properly transported, stored, handled, installed, and maintained. However, mold spores are present everywhere and when conditions are favorable; mold can grow on practically any surface. GYPSUM BOARD MUST BE KEPT DRY to prevent the growth of mold.
Gypsum board that has visible mold growth must not be used. For additional information refer to Gypsum Association publication, “Guidelines for the Prevention of Mold Growth on Gypsum Wallboard” (GA-238).
Gypsum board must be stored in an area that protects it from adverse weather conditions, condensation, and other forms of moisture. Job site conditions that can expose gypsum board to water or moisture must be avoided.
Gypsum board must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
Gypsum board must be stored off the ground and under protective cover. Sufficient risers must be used to assure support for the entire length of the wallboard to prevent sagging.
Gypsum board must be delivered to the job site as near to the time it will be used as possible. Individuals delivering gypsum board to jobsites should ensure that it is carried, not dragged, to place of storage/installation to prevent damage to finished edges.
Gypsum board shall always be stacked flat -NEVER on edge or end. Gypsum board stacked on edge or end is unstable and presents a serious hazard should it accidentally topple. Gypsum board should be placed so weight is evenly distributed and the floor is not overloaded.
Mold Resistance | Score of 10 (ASTM D 3273) |
---|---|
Manufacturing | ASTM C 1396 Federal Specification - SS-L-30D Type III Grade X |
Abrasion Resistance | Level 3 |
Indentation Resistance | Level 1 |
Soft Body Impact Resistance | Level 2 |
Hard Body Impact Resistance | Level 1 |
Surface Burning Characteristics | ASTM E 84 Flame Spread - 0 Smoke Developed - 0 |
LEED Contributions
Our products can contribute to the following credits within the Materials and Resources (MR) category.
Our products can contribute to the following credit within the Indoor Environmental Quality (IEQ) category.
To learn more please click the LEED link at right.
Call (866) 439-5800 or Send Email
Exterior Soffit wallboard is the ideal material for exterior soffit applications and sidewalls of protected exterior corridors/breezeways with indirect exposure to the weather. The panel contains a non-combustible gypsum core with its long edges being tapered, and ends being square-cut and finished smooth. Exterior Soffit wallboard is available in: 1/2” panels with a non-rated core, 5/8” Type X core for use in fire-rated assemblies, and a 5/8” Type C core (Special Order).
Products manufactured by American Gypsum contain no asbestos and no detectable levels of formaldehyde.
Exterior Soffit wallboard is a sag-resistant panel for use in exterior ceiling applications and sidewalls in protected exterior corridors/breezeways with indirect exposure to the weather. Uses include marquees, large canopies, covered walkways, parking areas, carports, exterior soffits and sidewalls of protected corridors/breezeways. The panels are secured directly to wood framing, cross-furring of wood, metal framing or metal furring channels attached to main supports.
With joints covered, Exterior Soffit wallboard will resist the passage of smoke. For additional information on smoke barriers, refer to Gypsum Association publication, “Building and Inspecting Smoke Barriers” (GA-618).
Exterior Soffit wallboard has achieved UL Environment’s GREENGUARD GOLD Certification. GREENGUARD Certified products are scientifically proven to meet some of the world’s most rigorous, third-party chemical emissions standards, helping reduce indoor air pollution and the risk of chemical exposure while avoiding in the creation of healthier indoor environments.
For more information, visit www.ul.com/gg.
Thickness | Widths | Lengths | Edge Types |
---|---|---|---|
1/2" (12.7mm) | 4' (1219mm) | 8' & 12' (2438mm & 3658mm) | Tapered |
5/8" Type X (15.9mm) | 4' (1219mm) | 8' - 12' (2438mm - 3658mm) | Tapered |
5/8" Type C (15.9mm) SPECIAL ORDER | 4' (1219mm) | 12' (3658mm) | Tapered |
Special lengths or edges may be available on special order. Consult your American Gypsum sales representative for details.
Gypsum board does not generate or support the growth of mold when it is properly transported, stored, handled, installed, and maintained. However, mold spores are present everywhere and when conditions are favorable; mold can grow on practically any surface. GYPSUM BOARD MUST BE KEPT DRY to prevent the growth of mold.
Gypsum board must be stored in an area that protects it from adverse weather conditions, condensation, and other forms of moisture. Job site conditions that can expose gypsum board to water or moisture must be avoided.
Gypsum board must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit only and must be promptly removed upon arrival of the load. Failure to remove the shipping bag can increase the likelihood of developing conditions favorable to the growth of mold.
Gypsum board that has visible mold growth must not be used. For additional information, refer to Gypsum Association publication,
"Guidelines for the Prevention of Mold Growth on Gypsum Wallboard" (GA-238).
Gypsum board must be stored off the ground and under protective cover. Sufficient risers must be used to assure support for the entire length of the wallboard to prevent sagging.
Gypsum board must be delivered to the job site as near to the time it will be used as possible. Individuals delivering gypsum board to jobsites should ensure that it is carried, not dragged, to place of storage/installation to prevent damage to finished edges.
Gypsum board shall always be stacked flat - NEVER on edge or end. Gypsum board stacked on edge or end is unstable and presents a serious hazard should it accidentally topple. Gypsum board should be placed so weight is evenly distributed and the floor is not overloaded.
Manufacturing | ASTM C 1396 section 8 (C 931) Federal Specification - None |
---|---|
Installation | ASTM C 840 Gypsum Association GA-216 |
Surface Burning Characteristics | ASTM E 84 Flame Spread 0 Smoke Developed 0 |
LEED Contributions
Our products can contribute to the following credits within the Materials and Resources (MR) category.
Our products can contribute to the following credit within the Indoor Environmental Quality (IEQ) category.
To learn more please click the LEED link at right.
Call (866) 439-5800 or Send Email